Customization: | Available |
---|---|
Warranty: | 2 Year |
Install: | Horizontal |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Types | DN15 | DN20 | DN25 |
Accuracy | Class2 | ||
leakage | 1.6Mpa water pressure, no leakage within 15 minutes. | ||
lenght | 165mm | 195mm | 225mm |
Overload flow | 3.125m³/h | 5m³/h | 7.875m³/h |
parmanent flow | 2.5m³/h | 4m³/h | 6.3m³/h |
Transitional flow | 0.05m³/h | 0.08m³/h | 0.126m³/h |
Minimum flow | 0.0313m³/h | 0.05m³/h | 0.0788m³/h |
Starting flow | ≤0.012m³/h | ≤0.016m³/h | 0.020m³/h |
Lowest reading | 0.0001m³ | ||
Largest reading | 99999.9999m³ | ||
Small flow errors | ≤±5% | ||
Flow errors | ≤±2% | ||
Work temperature : | 0-30(water meter) | ||
Work pressure : | 0.0--1.0Mpa |
Short code
Code |
Display Contents |
Code |
|
00 |
Balance credit |
70-79 |
Previous 10 times inputted water |
02 |
Full Display |
91 |
Software version |
03 |
Total water |
92 |
Meter No. |
04 |
Key version |
|
|
05 |
Tariff index |
94 |
SGC Code |
23 |
Alarm time(minute) |
96 |
Low Credit threshold |
24 |
Re-alarm time(minute) |
98 |
Current time |
36 |
Negative water |
99 |
Current date |
48 |
Token inputted times |
200~229 |
Previous 30 times charging time |
49 |
Tech token inputted times |
250~279 |
Previous 30 times charging TOKEN |
50~59 |
Previous 10 times token |
300~329 |
Previous 30 times charging m³ |
60~69 |
Previous 10 times Tech token |
|